Power Requirements: 120V-1ph-60hz-15amp service. A power ON/OFF switch is mounted on the control panel. The standard power connection is a 6' heavy duty power cord with NEMA 5-15 plug. This model can also be supplied for hard-wired installation.
Indicator Lights: Mounted on the face of the control panel: 1) POWER ON. 2) TANK HIGH LEVEL 3) STAND BY. 4) SUCTION. 5) DISCHARGE. The photo below illustrates the indicator lights as mounted on the 7000 machine.

Illustration of Indicator Lights on EVAC 7000 Machine Face

Construction Rugged steel frame with fully enclosed top and sides. The control panel is located in the upper front panel. The read panel opens to permit access to the interior.
Mounting: The unit is fitted with pads for floor mounting. It can also be bracket mounted on a lift structure or on a wall.
Extraction Hose: One 15' high temperature, oil service hose, complete with hydraulic grade fittings connecting the hose to the unit and to the extraction wand is supplied as standard.