Care and Cleaning

 Your EVAC 7000 is finished with a durable industrial-grade enamel. After installation, it's recommended that a good quality automotive wax be applied to the machine to protect the finish. To clean the machine, simply wipe with a soft cloth. Do not use harsh cleaners, solvents, or compounds.

 

Specifications - EVAC 7000

Type: Fixed Installation
Pump: Customized 1/2 HP, close coupled, heavy duty pump specifically configured to suction hot (up to 280 degrees F), petroleum based and synthetic engine auto and transmission oils only. No volatile fluids such as gasoline and/or brake fluid, coolant and GLS.
Operating Modes: a. Initiate

Suctions spent oil, via the engine dipstick access, into the unit's holding tank an automatically returns function control to "STANDBY" when "HIGH TANK LEVEL" is reached and the "HIGH TANK LEVEL" light light comes on.

b. Overboard

Discharges spent oil from the holding tank to the facility spent oil storage tank, and automatically shuts off when a preset safe "Low Tank Level" is reached. As a fail safe, if the level falls below the preset minimum level, the "Low Tank Level" light lights and the pump shuts off. Pump restarts once the level restored above minimum

Holding Tank: A 17-quart steel tank.
Valving: Electrically actuated, 3 port, free flow, ball valves with manual override. Operated from from a 3 position selector switch mounted on the control panel.
Extracted Oil Indicator: Electrical, float actuated. Digital meter, mounted on the face of the control panel, indicate the level of spent oil in the holding tank in 1/4 quart increments. A separate vacuum gauge mounted on the control panel indicates suction draw.