| Care and Cleaning
Your EVAC 7000 is finished with a durable industrial-grade
enamel. After installation, it's recommended that a good quality
automotive wax be applied to the machine to protect the finish. To clean
the machine, simply wipe with a soft cloth. Do not use harsh cleaners,
solvents, or compounds.
Specifications - EVAC 7000
| Type: |
Fixed Installation |
| Pump: |
Customized 1/2 HP, close coupled, heavy duty pump specifically
configured to suction hot (up to 280 degrees F), petroleum based
and synthetic engine auto and transmission oils only. No
volatile fluids such as gasoline and/or brake fluid, coolant and
GLS. |
| Operating Modes: |
a. Initiate
Suctions spent oil, via the engine dipstick access, into the
unit's holding tank an automatically returns function control to
"STANDBY" when "HIGH TANK LEVEL" is reached
and the "HIGH TANK LEVEL" light light comes on.
b. Overboard
Discharges spent oil from the holding tank to the facility
spent oil storage tank, and automatically shuts off when a
preset safe "Low Tank Level" is reached. As a fail
safe, if the level falls below the preset minimum level, the
"Low Tank Level" light lights and the pump shuts off.
Pump restarts once the level restored above minimum |
| Holding Tank: |
A 17-quart steel tank. |
| Valving: |
Electrically actuated, 3 port, free flow, ball valves with
manual override. Operated from from a 3 position selector switch
mounted on the control panel. |
| Extracted Oil Indicator: |
Electrical, float actuated. Digital meter, mounted on the face
of the control panel, indicate the level of spent oil in the
holding tank in 1/4 quart increments. A separate vacuum gauge
mounted on the control panel indicates suction draw. |
|